75 results found for 'Electrodes'. | View 25 per page Strip plurals: electrodes to electrod Electrodes to Electrodes
Low relevance matches: 14 other results may be of interest to you. Show low relevance matches
75 results found for 'Electrodes'. | View 25 per page
Low relevance matches: 14 other results may be of interest to you. Show low relevance matches
Vernier EKG Electrodes - Pack of 100
VERNIER EKG ELECTRODES
Each of the three leads on the EKG sensor connects to a disposable electrode. A pack of 100 disposable electrodes is included with the sensor. This is a replacement package of 100 electrodes for use with the EKG sensor.
Order code: ELEC
Hofmann Voltameter - Acrylic with Platinum Electrodes
HOFFMANN VOLTAMETER
A quality Australian made Hofmann Voltameter designed to overcome the problems associated with traditional glass voltameters like broken glassware, leaking rubber stoppers and electrodes.
The platinum electrodes are made from platinum wire and are f...
Order code: SC7312
IEC Electrodes Stainless Steel Adjustable Plate
IEC STAINLESS STEEL ADJUSTABLE PLATE ELECTRODES
This adjustable stainless steel plate electrode set is self contained and can be rested directly over the rim of a small beaker for studies in electrical conductivity in liquids. The 75mm long plates are insulated except for...
Order code: EM1790-001
IEC Electrodes Stainless Steel Plates Fixed Lamp
IEC STAINLESS STEEL FIXED PLATE ELECTRODES
This stainless steel fixed plate electrode set is self contained and can be rested directly over the rim of a small beaker for studies in electrical conductivity in liquids. The 50mm wide x 75mm long plates are fixed at a separat...
Order code: EM1791-001
IEC Electrodes Stainless Steel Rods Fixed Lamp
IEC STAINLESS STEEL FIXED ROD ELECTRODES
This stainless steel fixed rod electrode set is self contained and can fit inside a 10mm diameter test tube for studies in electrical conductivity in liquids. The 2mm diameter x 60mm long stainless steel rods are fixed at a separa...
Order code: EM1792-001
IEC Electrodes Stainless Steel 2 Rods Fixed Lamp and Flex Lead
IEC STAINLESS STEEL FIXED ROD ELECTRODES WITH CABLES
This stainless steel fixed rod electrode set is self contained and can fit inside a 10mm diameter test tube for studies in electrical conductivity in liquids. The 2mm diameter x 60mm long stainless steel rods are fixed...
Order code: EM1792-101
IEC Plate Electrodes - Carbon 100x50x6mm
IEC CARBON PLATE ELECTRODE 100x50x6mm
A plate of Carbon fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2360-001
IEC Plate Electrodes - Carbon 100x25x6mm
IEC CARBON PLATE ELECTRODE 100x25x6mm
A plate of Carbon fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2361-001
IEC Plate Electrodes - Copper 100x50x1.5mm
IEC COPPER PLATE ELECTRODE 100x50x1.5mm
A plate of Copper fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2370-001
IEC Plate Electrodes - Copper 100x50x3mm
IEC COPPER PLATE ELECTRODE 100x50x3mm
A plate of Copper fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2371-001
IEC Plate Electrodes - Copper 75x25x1.5mm
IEC COPPER PLATE ELECTRODE 75x25x1.5mm
A plate of Copper fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2372-001
IEC Plate Electrodes - Iron 100x50x1.5mm
IEC IRON PLATE ELECTRODE 100x50x1.5mm
A plate of Iron fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2380-001
IEC Plate Electrodes - Iron 75x25x1.5mm
IEC IRON PLATE ELECTRODE 75x25x1.5mm
A plate of Iron fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2381-001
IEC Plate Electrodes - Lead 100x50x1.5mm
IEC LEAD PLATE ELECTRODE 100x50x1.5mm
A plate of Lead fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2390-001
IEC Plate Electrodes - Lead 100x50x3mm
IEC LEAD PLATE ELECTRODE 100x50x3mm
A plate of Lead fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2391-001
IEC Plate Electrodes - Lead 75x25x1.5mm
IEC LEAD PLATE ELECTRODE 75x25x1.5mm
A plate of Lead fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2392-001
IEC Plate Electrodes - Zinc 100x50x1.5mm
IEC ZINC PLATE ELECTRODE 100x50x1.5mm
A plate of Zinc fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2400-001
IEC Plate Electrodes - Zinc 75x25x1.5mm
IEC ZINC PLATE ELECTRODE 75x25x1.5mm
A plate of Zinc fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2402-001
IEC Plate Electrodes - Stainless Steel 100x50x1.5mm
IEC STAINLESS STEEL PLATE ELECTRODE 100x50x1.5mm
A plate of Stainless Steel fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2410-001
IEC Plate Electrodes - Stainless Steel 75x25x1.5mm thick
IEC STAINLESS STEEL ELECTRODE 75x25x1.5mm
A plate of Stainless Steel fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2411-001
IEC Plate Electrodes - Tin 100x50x1.5mm
IEC TIN PLATE ELECTRODE 100x50x1.5mm
A plate of Tin fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2420-001
IEC Plate Electrodes - Tin 75x25x1.5mm
IEC TIN PLATE ELECTRODE 75x25x1.5mm
A plate of Tin fitted with a simple screw terminal to attach a wire for experiments with electrodes in conductivity and electrochemistry.
Order code: EM2421-001
IEC Rod Graphite/Carbon Electrodes 75x6mm Diameter
IEC GRAPHITE/CARBON ROD ELECTRODES 75mm
These versatile 75mm x 6mmD IEC quality graphite/carbon rods can be used for electrodes in various experiments involving current passing through liquids, experiments on heat, burning and many others.
Order code: EM3611-001
IEC Rod Graphite/Carbon Electrodes 150x6mm Diameter
IEC GRAPHITE/CARBON ROD ELECTRODES 150mm
These versatile 150mm x 6mmD IEC quality graphite/carbon rods can be used for electrodes in various experiments involving current passing through liquids, experiments on heat, burning and many others.
Order code: EM3611-005
IEC Rod Graphite/Carbon Electrodes 100x10mm Diameter
IEC GRAPHITE/CARBON ROD ELECTRODES 100mm
These versatile 100mm x 10mmD IEC quality graphite/carbon rods can be used for electrodes in various experiments involving current passing through liquids, experiments on heat, burning and many others.
Order code: EM3612-001
Hofmann Voltameter Electrodes Platinum Pair
A pair of platinum wire electrodes made in Australia with stainless steel electrical connections. Not cheap but made to last and address quality control problems associated with imported electrodes.
You will need to fit rubber stoppers to suit the diameter of your voltammeter....
Order code: SC7091
Hofmann Voltameter Electrodes Carbon Pair
A pair of carbon electrodes made in Australia with stainless steel electrical connections. Not cheap but made to last and address quality control problems associated with imported electrodes.
Order code: SC7092
Vernier Go Direct Cyclic Voltammetry System
VERNIER GO DIRECT CYCLIC VOLTAMMETRY SYSTEM
With the Vernier Go Direct Cyclic Voltammetry System, developed in part with Pine Research specialists in electrochemical research instrumentation, students can easily control and apply potential to a chemical system and measure...
Order code: GDX-CVS
Vernier Go Direct Conductivity Probe
VERNIER GO DIRECT CONDUCTIVITY PROBE
Vernier's Go Direct Conductivity Probe determines the ionic content of an aqueous solution by measuring its electrical conductivity. It directly connects wirelessly via Bluetooth® or wired via USB to your platform.
The Vernier Go Di...
Order code: GDX-CON
Vernier Go Direct ORP Sensor
VERNIER GO DIRECT ORP SENSOR
Vernier's Go Direct ORP (Oxidation-Reduction Potential) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. It directly connects wirelessly via Bluetooth® or wired via USB to your platform.
Use the Vernier Go...
Order code: GDX-ORP
Vernier Go Direct Calcium Ion-Selective Electrode
VERNIER GO DIRECT CALCIUM ION-SELECTIVE ELECTRODE
Vernier's Go Direct Calcium Ion-Selective Electrode (ISE) can be used to measure the concentration of calcium (Ca2+) in aqueous samples. It connects via Bluetooth® wireless technology or wired via USB to your device.
Da...
Order code: GDX-CA
Vernier Go Direct Chloride Ion-Selective Electrode
VERNIER GO DIRECT CHLORIDE ION-SELECTIVE ELECTRODE
Vernier's Go Direct Chloride Ion-Selective Electrode (ISE) is used to measure the concentration of chloride (Cl-) in aqueous samples. It connects via Bluetooth® wireless technology or wired via USB to your device.
The ...
Order code: GDX-CL
Vernier Go Direct Electrode Amplifier
VERNIER GO DIRECT ELECTRODE AMPLIFIER
Vernier's Go Direct Electrode Amplifier is an mV and pH amplifier that connects to Vernier electrodes and compatible third-party BNC electrodes. It directly connects wirelessly via Bluetooth® or wired via USB to your platform.
The ...
Order code: GDX-EA
Vernier Go Direct Ion-Selective Electrode Amplifier
VERNIER GO DIRECT ION-SELECTIVE ELECTRODE AMPLIFIER
Vernier's Go Direct Ion-Selective Electrode Amplifier is a mV and mg/L amplifier that connects to Vernier Ion-Selective Electrodes and compatible third-party BNC ion-selective electrodes. It connects via Bluetooth® wirel...
Order code: GDX-ISEA
Vernier Go Direct Potassium Ion-Selective Electrode
VERNIER GO DIRECT POTASSIUM ION-SELECTIVE ELECTRODE
Vernier's Go Direct Potassium Ion-Selective Electrode (ISE) can be used to measure the concentration of potassium (K+) ions in aqueous solutions. It connects via Bluetooth® wireless technology or wired via USB to your de...
Order code: GDX-K
Vernier Go Direct Ammonium Ion-Selective Electrode
VERNIER GO DIRECT AMMONIUM ION-SELECTIVE ELECTRODE
Vernier's Go Direct Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of ammonium (NH4+) in aqueous samples. It connects via Bluetooth® wireless technology or wired via USB to your device.
...
Order code: GDX-NH4
Vernier Go Direct Nitrate Ion-Selective Electrode
VERNIER GO DIRECT NITRATE ION-SELECTIVE ELECTRODE
The Vernier Go Direct Nitrate Ion-Selective Electrode (ISE) can be used to measure the concentration of nitrate (NO3-) in aqueous samples. It connects via Bluetooth® wireless technology or wired via USB to your device.
...
Order code: GDX-NO3
Vernier Conductivity Probe
VERNIER CONDUCTIVITY PROBE
The Vernier Conductivity Probe determines the ionic content of an aqueous solution by measuring its conductivity. This has many applications in chemistry, biology and environmental science.
Vernier's conductivity probe has three ranges provid...
Order code: CON-BTA
Vernier Salinity Sensor
VERNIER SALINITY SENSOR
The Vernier Salinity Sensor uses density and electrical conductivity to measure salinity. The Salinity Sensor easily and precisely measures the total dissolved salt content in an aqueous solution. Measure water with a wide variety of salinities, fr...
Order code: SAL-BTA-EB
Vernier EKG Sensor
VERNIER EKG SENSOR
The EKG Sensor measures electrical signals produced by the heart. It uses three disposable electrodes. An EKG graph is displayed, demonstrating to students the contraction and repolarisation of the heart's chambers. A package of 100 disposable electrode...
Order code: EKG-BTA
Vernier Electrode Amplifier
VERNIER ELECTRODE AMPLIFIER
The Electrode Amplifier is an ORP/mV/pH amplifier that accepts an electrode with a standard BNC connector. It amplifies a -450mV to +1100mV signal to a 0-5V range.
Use an Electrode Amplifier to collect data from almost any electrode that has...
Order code: EA-BTA
Vernier Ammonium Ion-Selective Electrode
VERNIER AMMONIUM ION-SELECTIVE ELECTRODE
Vernier's Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of ammonium (NH4+) in aqueous samples.
Use the Vernier Ammonium ISE to measure levels of ammonium ions introduced from fertilizers. It can...
Order code: NH4-BTA
Vernier Calcium Ion-Selective Electrode
VERNIER CALCIUM ION-SELECTIVE ELECTRODE
Vernier's Calcium Ion-Selective Electrode (ISE) can be used to measure the concentration of Calcium (Ca2+) in aqueous samples.
Data from the Vernier Calcium ISE can give a good indication of hardness of water (as Ca2+). The conce...
Order code: CA-BTA
Vernier Chloride Ion-Selective Electrode
VERNIER CHLORIDE ION-SELECTIVE ELECTRODE
Vernier's Chloride Ion-Selective Electrode (ISE) is used to measure the concentration of chloride (Cl-) in aqueous samples.
The concentration of the chloride ion gives a quick measurement of salinity of water samples. Use the Ve...
Order code: CL-BTA
Vernier Nitrate Ion-Selective Electrode
VERNIER NITRATE ION-SELECTIVE ELECTRODE
Vernier's Nitrate Ion-Selective Electrode (ISE) can be used to measure the concentration of Nitrate (NO3-) in aqueous samples.
Nitrate concentration, which can be increased by acidic rainfall, fertilizer runoff from fields and pl...
Order code: NO3-BTA
Vernier Potassium Ion-Selective Electrode
VERNIER POTASSIUM ION-SELECTIVE ELECTRODE
The Vernier Potassium Ion-Selective Electrode can be used to measure the concentration of potassium (K+) ions in aqueous solutions.
The Vernier Potassium Ion-Selective Electrode makes the measurement of potassium ions portable....
Order code: K-BTA
Vernier ORP Sensor
VERNIER ORP SENSOR
The Vernier ORP sensor measures the ability of a solution to act as an oxidising agent or reducing agent. ORP stands for oxidation-reduction potential. ORP electrodes are often used to measure the oxidising ability of chlorine in swimming pools or to de...
Order code: ORP-BTA
Vernier ORP Replacement Electrode
VERNIER ORP REPLACEMENT ELECTRODE
A replacement electrode for use with the ORP Sensor, the GW-EA Go!Wireless Electrode Amplifier and the EA-BTA Electrode Amplifier.
The Vernier ORP sensor measures the ability of a solution to act as an oxidising agent or reducing agen...
Order code: ORP-BNC
IEC Franck Hertz Experiment Set
IEC FRANCK HERTZ EXPERIMENT SET
The IEC 'Franck Hertz' experiment board consists of an electron valve configured as a miniature laboratory to detect the behaviour of Xenon gas atoms when bombarded with electrons. It is self-contained with an electron tube, a Thyratron, t...
Order code: AP1870-001
Vernier CVS Screen Printed Electrode 100 Pack
VERNIER GO DIRECT CVS SCREEN PRINTED ELECTRODES 100 PACK
These disposable low cost, screen printed electrodes are for use with the Vernier Go Direct Cyclic Voltammetry System and remove the hassle associated with polishing traditional electrodes.
Each electrode patter...
Order code: CVS-SPE100
Vernier CVS Screen Printed Electrode 25 Pack
VERNIER GO DIRECT CVS SCREEN PRINTED ELECTRODES 25 PACK
These disposable low cost, screen printed electrodes are for use with the Vernier Go Direct Cyclic Voltammetry System and remove the hassle associated with polishing traditional electrodes.
Each electrode pattern...
Order code: CVS-SPE25
IEC Electrode In Glass Norwood Set 4
IEC NORWOOD ELECTRODES IN GLASS SET 4
The IEC Norwood electrodes set includes a stainless steel electrode and a platinum electrode for various experiments in electrolysis plus two carbon electrodes for EMF or Redox cells. Each electrode is mounted in its own glass sleeve ...
Order code: EM1800-001
Vernier Go Wireless Heart Rate - Data Logger
Currently unavailable, we are awaiting confirmation it complies with Button Battery safety requirements.
VERNIER GO WIRELESS HEART RATE The Vernier Go Wireless Heart Rate is a pair of wireless hand grips that transmit heart rate onto a mobile device. Heart rate is measured by registering the small electrical signals carried across the surface of the skin each time the heart ... Order code: GW-HR
VERNIER GO WIRELESS HEART RATE The Vernier Go Wireless Heart Rate is a pair of wireless hand grips that transmit heart rate onto a mobile device. Heart rate is measured by registering the small electrical signals carried across the surface of the skin each time the heart ... Order code: GW-HR
IEC Air Track 2.5m Kit Spark Recorder
IEC AIR TRACK 2.5m SPARK RECORDER KIT
This Spark Recording Kit for the 2.5m long MF0105Z-001 IEC Air Track consists of a pair of special insulated tracks that carry the spark electrodes and a pair of insulated tracks that carry the paper tapes.
The LB0118-001 Spark Gene...
Order code: MF0105-401
IEC Air Track 2.0m Kit Spark Recorder
IEC AIR TRACK 2m SPARK RECORDER KIT
This Spark Recording Kit for the 2m long MF0107Z-001 IEC Air Track consists of a pair of special insulated tracks that carry the spark electrodes and a pair of insulated tracks that carry the paper tapes.
The LB0118-001 Spark Generato...
Order code: MF0107-401
IEC Electronics Kit Connector Box 2mm/4mm Plugs
IEC ELECTRONICS KIT CONNECTOR BOX FOR 2mm/4mm PLUGS
Circuits or electrodes in the EM1764-001 IEC Basic Electronics Kit can be connected together with this included connector box and adaptor for 2mm and 4mm banana plugs on a 17x38mm base with 4mm and 2mm sockets for connec...
Order code: PA1764-110
IEC Electrode In Glass Norwood Support Bracket
IEC NORWOOD ELECTRODE IN GLASS SUPPORT BRACKET
A spare plastic coated support frame for Norwood electrodes in glass as supplied with EM1800-001 IEC Electrode In Glass Norwood Set 4.
Order code: PA1800-005
IEC Stroboscope Xenon Flash Tube Only Spare
IEC XENON STROBOSCOPE FLASH TUBE ONLY
A spare 'U' shaped flash tube with 3 electrodes for providing high intensity and repetitive flashing.
Fits both LB3808-001 and LB3809-001 IEC Digital Xenon Stroboscopes.
Order code: PA3810-002
Vernier Electrode Storage Bottles
VERNIER ELECTRODE STORAGE BOTTLES
Use the Vernier Electrode Storage Bottles to ensure your Optical Dissolved Oxygen sensor or Ion-Selective Electrode is stored in a humid environment without the sensor tip being damaged by the sponge.
Sold as a pack of five bottles, e...
Order code: BTL-ES
Vernier Go Direct Calcium Ion-Selective Electrode BNC
VERNIER GO DIRECT CALCIUM ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-CA Vernier Go Direct™ Calcium Ion-Selective Electrode
Connect the Vernier Go Direct™ Calcium Ion-Selective Electrode BNC ...
Order code: GDX-CA-BNC
Vernier Go Direct Chloride Ion-Selective Electrode BNC
VERNIER GO DIRECT CHLORIDE ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-CL Vernier Go Direct™ Chloride Ion-Selective Electrode
Connect the Vernier Go Direct™ Chloride Ion-Selective Electrode B...
Order code: GDX-CL-BNC
Vernier Go Direct Potassium Ion-Selective Electrode BNC
VERNIER GO DIRECT POTASSIUM ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-K Vernier Go Direct™ Potassium Ion-Selective Electrode
Connect the Vernier Go Direct Potassium Ion-Selective Electrode ...
Order code: GDX-K-BNC
Vernier Go Direct Ammonium Ion-Selective Electrode BNC
VERNIER GO DIRECT AMMONIUM ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-NH4 Vernier Go Direct™ Ammonium Ion-Selective Electrode
Connect the Vernier Go Direct™ Ammonium Ion-Selective Electrode ...
Order code: GDX-NH4-BNC
Vernier Go Direct Nitrate Ion-Selective Electrode BNC
VERNIER GO DIRECT NITRATE ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-NO3 Vernier Go Direct™ Nitrate Ion-Selective Electrode
Connect the Vernier Go Direct™ Nitrate Ion-Selective Electrode BNC...
Order code: GDX-NO3-BNC
Vernier Electrode Support
VERNIER ELECTRODE SUPPORT
Vernier's Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts and its large-handled locking nut keeps your sensors firmly in pl...
Order code: ESUP
Vernier ISE Ammonium Replacement Module
VERNIER ISE AMMONIUM REPLACEMENT MODULE
The Vernier Ammonium Ion-Selective Electrode Module replaces the electrode membrane. Simply unscrew the old one and screw on the new one.
The membrane of a Vernier Ammonium ISE electrode has a limited life span of one to two yea...
Order code: NH4-MOD
Vernier ISE Calcium Replacement Module
VERNIER ISE CALCIUM REPLACEMENT MODULE
The Vernier Calcium Ion-Selective Electrode Module replaces the electrode membrane. Simply unscrew the old one and screw on the new one.
The membrane of a Vernier Calcium ISE electrode has a limited life span of one to two years ...
Order code: CA-MOD
Vernier ISE Nitrate Replacement Module
VERNIER ISE NITRATE REPLACEMENT MODULE
The Vernier Nitrate Ion-Selective Electrode Module replaces the electrode membrane. Simply unscrew the old one and screw on the new one.
The membrane of a Vernier Nitrate ISE electrode has a limited life span of one to two years,...
Order code: NO3-MOD
Vernier pH Electrode BNC
VERNIER PH ELECTRODE
This is a replacement electrode only. It will NOT work without either EA-BTA Vernier Electrode Amplifier or the discontinued Vernier Go Wireless Electrode Amplifier
This Vernier gel-filled...
Order code: PH-BNC
Vernier ISE Potassium High Standard
VERNIER ISE POTASSIUM HIGH STANDARD SOLUTION
High quality, uncontaminated standards are critical for proper calibration of Ion-Selective Electrodes. This 500mL solution has a concentration of 1000mg/L and is for use with the Potassium ISE.
Order code: K-HST
Vernier ISE Potassium Low Standard
VERNIER ISE POTASSIUM LOW STANDARD SOLUTION
High quality, uncontaminated standards are critical for proper calibration of Ion-Selective Electrodes. This 500mL solution has a concentration of 10mg/L and is for use with the Potassium ISE.
Order code: K-LST
Vernier ISE Potassium Replacement Module
VERNIER ISE POTASSIUM REPLACEMENT MODULE
The Vernier Potassium Ion-Selective Electrode Module replaces the electrode membrane. Simply unscrew the old one and screw on the new one.
The membrane of a Vernier Potassium ISE electrode has a limited life span of one to two ...
Order code: K-MOD
IEC Electrode In Glass Norwood Spare Carbon
IEC CARBON NORWOOD ELECTRODE IN GLASS
A spare carbon rod electrode for EM1800-001 IEC Electrode In Glass Norwood Set 4.
Order code: PA1800-002
IEC Electrode In Glass Norwood Spare Stainless Steel
IEC STAINLESS STEEL NORWOOD ELECTRODE IN GLASS
A spare stainless steel rod electrode in glass for EM1800-001 IEC Electrode In Glass Norwood Set 4.
Order code: PA1800-003
IEC Electrode In Glass Norwood Spare Platinum
IEC PLATINUM NORWOOD ELECTRODE IN GLASS
A spare platinum wire electrode in glass for EM1800-001 IEC Electrode In Glass Norwood Set 4.
Order code: PA1800-004
75 results found for 'Electrodes'. | View 25 per page