Scientific Equipment Supplier
Vernier Science Education Data Logger DistributorLog in 
Cart/Quote $0 ex GST0 items
                                Check out our new WiFi Weather Station                               
        
               LabQuest 2 App Version 2.9 Update released - supports GoDirect wireless sensors                                Check out our new WiFi Weather Station                               
        
               LabQuest 2 App Version 2.9 Update released - supports GoDirect wireless sensors                                Check out our new WiFi Weather Station                               
        
               LabQuest 2 App Version 2.9 Update released - supports GoDirect wireless sensors                                Check out our new WiFi Weather Station                               
        
               LabQuest 2 App Version 2.9 Update released - supports GoDirect wireless sensors                                Check out our new WiFi Weather Station                               
        
               LabQuest 2 App Version 2.9 Update released - supports GoDirect wireless sensors
gdx-dc-1.jpg
Go Direct Drop Counter with inclusions.
Enlarge
gdx-dc.jpg

Enlarge
gdx-dc-2.jpg

Enlarge
gdx-crg.jpg
Purchase GDX-CRG to recharge multiple Go Direct sensors
Enlarge
gdx-dc-1.jpg
Go Direct Drop Counter with inclusions.
Enlarge
gdx-dc.jpg

Enlarge
gdx-dc-2.jpg

Enlarge
gdx-crg.jpg
Purchase GDX-CRG to recharge multiple Go Direct sensors
Enlarge

Vernier Go Direct Drop Counter

Order code: GDX-DC
Purchase QTY: (Each) 1+
Scientrific's price   $262.00
Note: Prices do NOT include GST or freight

VERNIER GO DIRECT DROP COUNTER
Vernier's Go Direct Drop Counter precisely records the number of drops of titrant added during a titration and then automatically converts it to volume. It directly connects wirelessly via Bluetooth® or wired via USB to your platform.

Conducting a titration has never been easier. Use the Vernier Go Direct Drop Counter in conjunction with other Vernier Go Direct sensors, such as Go Direct pH, Go Direct Conductivity or Go Direct ORP, to perform acid-base, conductometric or potentiometric titrations.

Designed with a wide drop-detecting area, Vernier Go Direct Drop Counter removes the need for precise burette alignment. Vernier has also included a large sensor slot for conventional stick-style sensors and a smaller, adjustable slot for temperature probes. The adjustable clamp easily fits the Vernier Stir Station and most laboratory ring stands and lattices.

Rechargeable Battery — Ready When You Are
The Vernier Go Direct™ robust rechargeable battery offers long battery life and provides always-ready operation. Monitor battery life directly from Vernier's free Graphical Analysis™ app Should the battery run low simply connect the sensor to the charging cable and keep on collecting — no interruptions or inconvenience to you or your students.

Wired or Wireless — The Flexibility to Choose
Vernier's Go Direct™ sensors connect directly to your mobile device, Chromebook or computer using Vernier's free Graphical Analysis™ app. No additional equipment or software purchases are necessary. Vernier Go Direct sensors can be used wired via USB or wirelessly via Bluetooth allowing you to choose the solution best for your classroom or laboratory.

Vernier Graphical Analysis™ Pro includes all the features of the free Vernier Graphical Analysis app, plus enhanced functions for more advanced analysis. Its illustrative experiment videos and interactive graphing capabilities inspire students to explore crucial scientific concepts and analyze data in new complex and insightful ways.
Vernier Graphical Analysis™ Pro is compatible with most Vernier sensors and multiple operating systems and devices.

Specifications:
• Accurate drop counting at rates up to 6 drops/s
• Dimensions:
     Opening for drops: 3cm
     Openings for sensors (diameter): 7mm and 13mm
     Ring stand opening: 16mm
     Total length: 15.5cm, width: 4.5cm, height: 1.8cm
     Distance from centre of ring stand opening to centre of drop opening (ideal): 10.5cm
     Distance from centre of ring stand opening to centre of sensor opening (ideal): 12cm
•Connections:
     Wireless: Bluetooth
     Wired: USB

Included:
• Vernier Go Direct Drop Counter
• Plastic reagent reservoir
• Plastic valve with a double stopcock fitting
• Vernier Microstirrer
• Vernier Micro USB Cable

User ManualVernier Go Direct Drop Counter

Educational use only:
Vernier and Kidwind products are designed for educational use. They are not appropriate for industrial, medical or commercial applications. Details


Warranty
  • Warranty: 5 year limited warranty (1 year on battery)
    Dimensions
    • Package size (HxWxD): 57x89x178mm
    • Packed weight: 180g

      Last edited 29th Jan 2024

      This product is used in teaching these Australian Curriculum codes:
      ACSCH063 - Molecular interactions and reactions - Aqueous solutions and acidity - The concentration of a solution is defined as the amount of solute divided by the amount of solution; this can be represented in a variety of ways including by the number of moles of the solute per litre of solution (mol L­1) and the mass of the solute pe
      ACSCH066 - Molecular interactions and reactions - Aqueous solutions and acidity - The pH scale is used to compare the levels of acidity or alkalinity of aqueous solutions; the pH is dependent on the concentration of hydrogen ions in the solution
      ACSCH064 - Molecular interactions and reactions - Aqueous solutions and acidity - The presence of specific ions in solutions can be identified using analytical techniques based on chemical reactions, including precipitation and acid­base reactions
      ACSCH097 - Equilibrium acids and redox reactions - Chemical equilibrium systems - Acids are substances that can act as proton (hydrogen ion) donors and can be classified as monoprotic or polyprotic depending on the number of protons donated by each molecule of the acid
      ACSCH101 - Equilibrium acids and redox reactions - Chemical equilibrium systems - Acid­base indicators are weak acids or bases where the acidic form is of a different colour to the basic form
      ACSCH091 - Equilibrium acids and redox reactions - Chemical equilibrium systems - Over time, physical changes and reversible chemical reactions reach a state of dynamic equilibrium in a closed system, with the relative concentrations of products and reactants defining the position of equilibrium
      ACSCH100 - Equilibrium acids and redox reactions - Chemical equilibrium systems - The pH scale is a logarithmic scale and the pH of a solution can be calculated from the concentration of hydrogen ions; Kw can be used to calculate the concentration of hydrogen ions from the concentration of hydroxide ions in a solution
      ACSCH099 - Equilibrium acids and redox reactions - Chemical equilibrium systems - The relationship between acids and bases in equilibrium systems can be explained using the Brønsted­ Lowry model and represented using chemical equations that illustrate the transfer of hydrogen ions
      ACSCH098 - Equilibrium acids and redox reactions - Chemical equilibrium systems - The strength of acids is explained by the degree of ionisation at equilibrium in aqueous solution, which can be represented with chemical equations and equilibrium constants (Ka)
      ACSCH102 - Equilibrium acids and redox reactions - Chemical equilibrium systems - Volumetric analysis methods involving acid­base reactions rely on the identification of an equivalence point by measuring the associated change in pH, using chemical indicators or pH meters, to reveal an observable end point

      Click a curriculum code to see other products that relate.

       
      Accessories / Spare Parts:From
      CB-USB-MICRO - Vernier Micro USB Cable $12.00
      CB-USB-C-MICRO - Vernier Micro USB-C Cable $22.00
      GDX-CRG - Vernier Go Direct Charging Station $219.00
      GDX-BAT-300 - Vernier Go Direct 300mAH Replacement Battery $24.00
       
      Works with:From
      LQ3 - Vernier LabQuest 3 Data Logger and Interface$972.00
      GA4 - Vernier Graphical Analysis$0.00
      GAP-1Y - Vernier Graphical Analysis Pro 1 Year$331.00
       
      Similar Products:From
      GDX-TMP - Vernier Go Direct Temperature Probe$188.00
      GDX-SVISPL - Vernier Go Direct SpectroVis Plus Spectrophotometer - Spectrometer$1,116.00
      GDX-WRT - Vernier Go Direct Wide Range Temperature Probe$334.00
      GDX-ST - Vernier Go Direct Surface Temperature Sensor$238.00
      GDX-PH - Vernier Go Direct pH Sensor$262.00
      GDX-ACC - Vernier Go Direct Acceleration Sensor$274.00
      GDX-FOR - Vernier Go Direct Force and Acceleration Sensor$286.00
      GDX-FPH - Vernier Go Direct Tris Compatible Flat pH Sensor$322.00
      GDX-GPH - Vernier Go Direct Glass-Body pH Sensor$382.00
      GDX-CCS - Vernier Go Direct Constant Current System$241.00
      GDX-CUR - Vernier Go Direct Current Probe$238.00
      GDX-RB - Vernier Go Direct Respiration Belt$286.00
      GDX-RMS - Vernier Go Direct Rotary Motion Sensor$455.00
      GDX-MLT - Vernier Go Direct Melt Station$1,453.00
      GDX-3MG - Vernier Go Direct 3-Axis Magnetic Field Sensor$214.00
      GDX-CON - Vernier Go Direct Conductivity Probe$310.00
      GDX-COL - Vernier Go Direct Colorimeter$310.00
      GDX-GP - Vernier Go Direct Gas Pressure Sensor$238.00
      GDX-LC - Vernier Go Direct Light and Colour Sensor$238.00
      GDX-MD - Vernier Go Direct Motion Detector$298.00
      GDX-ORP - Vernier Go Direct ORP Sensor$286.00
      GDX-RAD - Vernier Go Direct Radiation Monitor - Geiger Counter$527.00
      GDX-VOLT - Vernier Go Direct Voltage Probe$214.00
      GDX-EA - Vernier Go Direct Electrode Amplifier$190.00

      Documents:
      CatalogueVernier Catalogue K-12
      CatalogueVernier Catalogue Uni
      CatalogueMay 2024 Web Catalogue
      Compatibility GuideSensor-Interface-Software Requirements (external link)
      User ManualVernier Go Direct Drop Counter

      Note: Prices do NOT include GST or freight