Vernier Go Direct Chloride Ion-Selective Electrode BNC
Order code: GDX-CL-BNCVERNIER GO DIRECT CHLORIDE ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-CL Vernier Go Direct™ Chloride Ion-Selective Electrode
Connect the Vernier Go Direct™ Chloride Ion-Selective Electrode BNC to Vernier's Go Direct™ Ion-Selective Electrode Amplifier to measure the concentration of chloride (Cl-) ions in aqueous samples.
Vernier's Go Direct™ Vernier Chloride Ion-Selective Electrode BNC is a BNC-terminated electrode and
requires a Vernier Go Direct™ Ion-Selective Electrode Amplifier.
It is possible to use it with the GDX-EA Vernier Go Direct Electrode Amplifier but measurements will be the potential (mV) and calculation is necessary to convert to mg/L or ppm.
Specifications:
• Range (mV): Vernier Go Direct™ Ion-Selective Electrode Amplifier: -1000mV to +1000mV
• Range (concentration): 1 to 35,000mg/L (or ppm)
• Reproducibility (precision): ±30mV
• Interfering ions: CN–, Br–, I–, S2-, OH–, NH3
• pH range: 2–12 (no pH compensation)
• Temperature range: 0–80°C (no temperature compensation)
• Electrode slope: 56 ±3mV/decade at 25°C
• Electrode resistance: 1 to 5 MΩ
• Minimum sample size: must be submerged 28mm
Included:
• Vernier Go Direct™ Chloride Ion-Selective Electrode with BNC terminated end, packed with a storage bottle
• 30mL bottle of High Standard solution with SDS (100mg/L Cl–)
• 30mL bottle of Low Standard solution with SDS (1mg/L Cl–)
• Short-Term ISE Soaking Bottle
User Manual | Vernier Go Direct Chloride Ion-Selective Electrode |
Educational use only:
Vernier and Kidwind products are designed for educational use. They are not appropriate for industrial, medical or commercial applications. Details
Warranty
- Warranty: 1 year
Dimensions- Package size (HxWxD): 102x102x311mm
- Packed weight: 320g
Last edited 23rd Jan 2024
ACSCH030 - Chemical fundamentals - Properties and structure of materials - Ions are atoms or groups of atoms that are electrically charged due to an imbalance in the number of electrons and protons; ions are represented by formulae which include the number of constituent atoms and the charge of the ion (for example, O2–, SO42–)
ACSCH032 - Chemical fundamentals - Properties and structure of materials - The characteristic properties of metals (for example, malleability, thermal conductivity, electrical conductivity) are explained by modelling metallic bonding as a regular arrangement of positive ions (cations) made stable by electrostatic forces of attra
ACSCH031 - Chemical fundamentals - Properties and structure of materials - The properties of ionic compounds (for example, high melting point, brittleness, ability to conduct electricity when liquid or in solution) are explained by modelling ionic bonding as ions arranged in a crystalline lattice structure with forces of attract
ACSSU176 - Biological Sciences - Ecology - Ecosystems consist of communities of interdependent organisms and abiotic components of the environment; matter and energy flow through these systems
Click a curriculum code to see other products that relate.
  | |
Works with: | From |
GA4 - Vernier Graphical Analysis | $0.00 |
GDX-ISEA - Vernier Go Direct Ion-Selective Electrode Amplifier | $190.00 |
GDX-EA - Vernier Go Direct Electrode Amplifier | $190.00 |
BTL-ES - Vernier Electrode Storage Bottles | $36.00 |
CL-LST - Vernier ISE Chloride Low Standard | $60.00 |
CL-HST - Vernier ISE Chloride High Standard | $60.00 |
  | |
Similar Products: | From |
GDX-NH4 - Vernier Go Direct Ammonium Ion-Selective Electrode | $695.00 |
GDX-K - Vernier Go Direct Potassium Ion-Selective Electrode | $695.00 |
GDX-CA - Vernier Go Direct Calcium Ion-Selective Electrode | $695.00 |
GDX-CL - Vernier Go Direct Chloride Ion-Selective Electrode | $695.00 |
GDX-NO3 - Vernier Go Direct Nitrate Ion-Selective Electrode | $695.00 |
GDX-FPH-BNC - Vernier Go Direct Flat pH BNC Electrode | $200.00 |
GDX-GPH-BNC - Vernier Go Direct Glass Body pH BNC Electrode | $226.00 |
GDX-PH-BNC - Vernier Go Direct pH BNC Electrode | $120.00 |
GDX-ORP-BNC - Vernier Go Direct ORP BNC Electrode | $142.00 |
GDX-NO3-BNC - Vernier Go Direct Nitrate Ion-Selective Electrode BNC | $599.00 |
GDX-NH4-BNC - Vernier Go Direct Ammonium Ion-Selective Electrode BNC | $599.00 |
GDX-K-BNC - Vernier Go Direct Potassium Ion-Selective Electrode BNC | $599.00 |
GDX-CA-BNC - Vernier Go Direct Calcium Ion-Selective Electrode BNC | $599.00 |
CL-BTA - Vernier Chloride Ion-Selective Electrode | $719.00 |
CL-BNC - Vernier Chloride Ion-Selective Electrode BNC | $601.00 |
Documents: Catalogue | Vernier Catalogue K-12 | Catalogue | Vernier Catalogue Uni | Catalogue | May 2024 Web Catalogue | Compatibility Guide | Sensor-Interface-Software Requirements (external link) | User Manual | Vernier Go Direct Chloride Ion-Selective Electrode | |
Note: Prices do NOT include GST or freight