ACSSU176: Year 9 Biological Sciences - Ecology
Ecosystems consist of communities of interdependent organisms and abiotic components of the environment; matter and energy flow through these systems
Related documents
Category | Title | Type |
---|---|---|
Experiment | MS Schoolyard study | |
Experiment | MS Biodiversity | |
Experiment | MS Ecocolumn investigations |
Scientrific can supply the following products used in performing the experiments in the above PDF/s:
This search is limited to Australian Curriculum codes only. Please click here to search the whole catalogue.
Displaying results page 2 of 3 | 71 results found.
Displaying results page 2 of 3 | 71 results found.
Vernier Go Direct Potassium Ion-Selective Electrode
VERNIER GO DIRECT POTASSIUM ION-SELECTIVE ELECTRODE
Vernier's Go Direct Potassium Ion-Selective Electrode (ISE) can be used to measure the concentration of potassium (K+) ions in aqueous solutions. It connects via Bluetooth® wireless technology or wired via USB to your de...
Order code: GDX-K
Vernier Go Direct Ammonium Ion-Selective Electrode BNC
VERNIER GO DIRECT AMMONIUM ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-NH4 Vernier Go Direct™ Ammonium Ion-Selective Electrode
Connect the Vernier Go Direct™ Ammonium Ion-Selective Electrode ...
Order code: GDX-NH4-BNC
Vernier Go Direct Calcium Ion-Selective Electrode BNC
VERNIER GO DIRECT CALCIUM ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-CA Vernier Go Direct™ Calcium Ion-Selective Electrode
Connect the Vernier Go Direct™ Calcium Ion-Selective Electrode BNC ...
Order code: GDX-CA-BNC
Vernier Go Direct Chloride Ion-Selective Electrode BNC
VERNIER GO DIRECT CHLORIDE ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-CL Vernier Go Direct™ Chloride Ion-Selective Electrode
Connect the Vernier Go Direct™ Chloride Ion-Selective Electrode B...
Order code: GDX-CL-BNC
Vernier Go Direct Flat pH BNC Electrode
VERNIER GO DIRECT FLAT pH BNC ELECTRODE
Connect the Flat pH BNC Electrode to Vernier's Go Direct™ Electrode Amplifier to measure pH of solutions containing proteins or sulfides.
The glass membrane is flat instead of a bulb, making it more durable, easier to clean and a...
Order code: GDX-FPH-BNC
Vernier Go Direct Glass Body pH BNC Electrode
VERNIER GO DIRECT GLASS BODY pH BNC ELECTRODE
Connect the Glass-Body pH BNC Electrode to Vernier's Go Direct™ Electrode Amplifier to measure pH in aqueous, heterogeneous and organic solutions.
This high-quality glass body pH electrode can be used in non-aqueous solutio...
Order code: GDX-GPH-BNC
Vernier Go Direct Nitrate Ion-Selective Electrode BNC
VERNIER GO DIRECT NITRATE ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-NO3 Vernier Go Direct™ Nitrate Ion-Selective Electrode
Connect the Vernier Go Direct™ Nitrate Ion-Selective Electrode BNC...
Order code: GDX-NO3-BNC
Vernier Go Direct Potassium Ion-Selective Electrode BNC
VERNIER GO DIRECT POTASSIUM ION-SELECTIVE ELECTRODE BNC
This is a replacement electrode for GDX-K Vernier Go Direct™ Potassium Ion-Selective Electrode
Connect the Vernier Go Direct Potassium Ion-Selective Electrode ...
Order code: GDX-K-BNC
Vernier Light Sensor - Lux Meter
VERNIER LIGHT SENSOR
Vernier's Light Sensor approximates the human eye in spectral response and can be used over three different illumination ranges selected with a switch. Use it for inverse square law experiments, studying polarizers, reflectivity or solar energy.
Th...
Order code: LS-BTA
Vernier Conductivity Probe
VERNIER CONDUCTIVITY PROBE
The Vernier Conductivity Probe determines the ionic content of an aqueous solution by measuring its conductivity. This has many applications in chemistry, biology and environmental science.
Vernier's conductivity probe has three ranges provid...
Order code: CON-BTA
Vernier Salinity Sensor
VERNIER SALINITY SENSOR
The Vernier Salinity Sensor uses density and electrical conductivity to measure salinity. The Salinity Sensor easily and precisely measures the total dissolved salt content in an aqueous solution. Measure water with a wide variety of salinities, fr...
Order code: SAL-BTA-EB
Vernier Turbidity Sensor
VERNIER TURBIDITY SENSOR
Vernier's Turbidity Sensor can be used in Chemistry, Biology, Water Quality, Physical Science and Earth Science studies to measure the turbidity of freshwater or seawater samples. Its small, sleek design and simple set up make it easy to use at th...
Order code: TRB-BTA
Vernier Soil Moisture Sensor
VERNIER SOIL MOISTURE SENSOR
The Soil Moisture Sensor uses capacitance to measure the water content of soil by measuring the dielectric permittivity of the soil - a function of the water content. Simply insert this rugged sensor into the soil to be tested, and the volumet...
Order code: SMS-BTA
Vernier CO2 Gas Sensor
VERNIER CO2 GAS SENSOR
The Vernier CO2 Gas Sensor equips students to easily monitor changes in CO2 levels occurring in respiration of organisms ranging from peas to humans.
The sensor measures gaseous carbon dioxide levels from 0 to 100,000 ppm in two ranges:
• Low ran...
Order code: CO2-BTA
Vernier UVA Sensor
VERNIER UVA SENSOR
The Vernier UVA Sensor is an ultraviolet light sensor that responds primarily to UVA radiation (approximately 320 to 390nm).
It is ideal for experiments using UV lamps.
UVB-BTA Vernier UVB Sensor ...
Order code: UVA-BTA
Vernier UVB Sensor
VERNIER UVB SENSORS
The Vernier UVB Sensor is an ultraviolet light sensor that responds primarily to UVB radiation (approximately 290 to 320nm).
It is ideal for experiments using sunlight as your UV source and is the sensor recommended for the UV experiments in Vernier l...
Order code: UVB-BTA
Vernier Gas Pressure Sensor
VERNIER GAS PRESSURE SENSOR
Vernier's Gas Pressure Sensor can be used to monitor pressure changes in a gas. The range is wide enough to perform Boyle’s law yet it is sensitive enough to conduct vapour-pressure or pressure-temperature experiments.
Biology teachers can us...
Order code: GPS-BTA
Vernier O2 Oxygen Gas Sensor
VERNIER O2 GAS SENSOR
Vernier's O2 Gas Sensor measures oxygen concentration in air and is temperature compensated for use in different environments. It has a wide measurement range allowing it to be used to study human and cellular respiration.
The O2 Gas Sensor can b...
Order code: O2-BTA
Vernier Ammonium Ion-Selective Electrode
VERNIER AMMONIUM ION-SELECTIVE ELECTRODE
Vernier's Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of ammonium (NH4+) in aqueous samples.
Use the Vernier Ammonium ISE to measure levels of ammonium ions introduced from fertilizers. It can...
Order code: NH4-BTA
Vernier Calcium Ion-Selective Electrode
VERNIER CALCIUM ION-SELECTIVE ELECTRODE
Vernier's Calcium Ion-Selective Electrode (ISE) can be used to measure the concentration of Calcium (Ca2+) in aqueous samples.
Data from the Vernier Calcium ISE can give a good indication of hardness of water (as Ca2+). The conce...
Order code: CA-BTA
Vernier Chloride Ion-Selective Electrode
VERNIER CHLORIDE ION-SELECTIVE ELECTRODE
Vernier's Chloride Ion-Selective Electrode (ISE) is used to measure the concentration of chloride (Cl-) in aqueous samples.
The concentration of the chloride ion gives a quick measurement of salinity of water samples. Use the Ve...
Order code: CL-BTA
Vernier Nitrate Ion-Selective Electrode
VERNIER NITRATE ION-SELECTIVE ELECTRODE
Vernier's Nitrate Ion-Selective Electrode (ISE) can be used to measure the concentration of Nitrate (NO3-) in aqueous samples.
Nitrate concentration, which can be increased by acidic rainfall, fertilizer runoff from fields and pl...
Order code: NO3-BTA
Vernier Potassium Ion-Selective Electrode
VERNIER POTASSIUM ION-SELECTIVE ELECTRODE
The Vernier Potassium Ion-Selective Electrode can be used to measure the concentration of potassium (K+) ions in aqueous solutions.
The Vernier Potassium Ion-Selective Electrode makes the measurement of potassium ions portable....
Order code: K-BTA
Vernier Relative Humidity Sensor
VERNIER RELATIVE HUMIDITY SENSOR
Vernier's Relative Humidity Sensor contains an integrated circuit that can be used to monitor relative humidity
over the range 0 to 95% (± 5%). The sensor has applications in weather studies, monitoring greenhouses
or for determining d...
Order code: RH-BTA
Vernier BioChamber 250
VERNIER BIOCHAMBER 250
The Vernier BioChamber is useful for experiments investigating photosynthesis and cell respiration. The Vernier BioChamber 250 is a 250mL Nalgene bottle that can be used with a Vernier CO2 Gas Sensor or Vernier Go Direct CO2 Gas Sensor and a Vernier...
Order code: BC-250